IFC SDK API contains a set of functions that implements SDAI functionality. To get additional information about these functions, see the SDAI functions documentation.
All SDAI functions have either "_sdai"
or "sdai"
prefixes in their names.
Functions that start with the "_sdai"
prefix are special IFC SDK utility functions, which
are not specified in the SDAI specification.
SDAI operations are performed within an SDAI session.
When an operation fails, the appropriate error code can be retrieved by using the
sdaiErrorQuery()
function.
You can use this function to determine what went wrong during the SDAI session and report the error details to a user.
In cases when the operation is successful, this function returns the sdaiNO_ERR
value.
Error codes are collected at the error query using FIFO rules ("First In - First Out").
Each call of the sdaiErrorQuery()
function removes the last error state from the error queue.
A common workflow with the SDAI programming interface in IFC SDK contains the following steps:
sdaiOpenSession()
function:
SdaiSession session = sdaiOpenSession();
if ((!session) || (sdaiErrorQuery() != sdaiNO_ERR))
return;
To be sure that the session is created successfully, check the returned value and the last error.
SdaiTestAppServices* appServices = (SdaiTestAppServices*)pHostApp;
if(!appServices)
return;
OdString pathToFile = L"Ifc4/rac_basic_sample_project_4_low.ifc";
OdAnsiString pathToFileDirectory = static_cast < OdAnsiString > (appServices->formatPathToBugDirectory(pathToFile));
SdaiString sdaiPathToFileDirectory = const_cast < SdaiString > (pathToFileDirectory.c_str());
SdaiString nameRepo = "";
SdaiRep repoCreate = _sdaiCreateRepositoryFromFile(session, sdaiPathToFileDirectory, nameRepo);
if ((!repoCreate) || (sdaiErrorQuery() != sdaiNO_ERR))
return;
repoCreate = sdaiOpenRepository(session, repoCreate);
Also see related SDAI functions:
SdaiString modelName = "default";
SdaiAccessMode accessMode = sdaiRO;
SdaiModel model = sdaiAccessModelBN(repoCreate, modelName, accessMode);
If ((!model) || (sdaiErrorQuery() != sdaiNO_ERR))
return;
See the sdaiAccessModelBN()
function documentation for additional information.
Now the model is open in read-only mode and is ready for use. For example, you can get access to application instances.
DATA
section.
Each string represents an application instance and has the following structure:
#HANDLE=INSTANCE_TYPE(INSTANCE_PARAM_1_VALUE, ... , INSTANCE_PARAM_N_VALUE);
HANDLE
— Contains the handle value. The handle identifies the instance inside the DATA
section.
INSTANCE_TYPE
— The instance type.
INSTANCE_PARAM_1_VALUE
— The value of the first instance parameter.
INSTANCE_PARAM_N_VALUE
— The value of the last instance parameter.
The quantity and datatype instance parameters are specified by the schema definition.
It is possible to get access to an application instance through its handle value:
use the _sdaiGetEntityById()
function call as in the code fragment below:
//#5 = IFCAPPLICATION(#1, '2019', 'Autodesk Revit 2019 (ENU)', 'Revit');
SdaiAppInstance applicationInstance = _sdaiGetEntityById(model, 5);
if ((!applicationInstance) || (sdaiErrorQuery() != sdaiNO_ERR))
return;
To get a handle value of the application instance, use the
_sdaiGetEntityId()
function.
To find out whether the application instance belongs to an appropriate instance type, call the
sdaiIsInstanceOfBN()
function and then check the result it returns.
SdaiInteger handle = _sdaiGetEntityId(applicationInstance);
SdaiBoolean isInstanceOf = sdaiIsInstanceOfBN(applicationInstance, "IFCAPPLICATION");
if((handle != 5) || (isInstanceOf != sdaiTRUE) || (sdaiErrorQuery() != sdaiNO_ERR))
return;
sdaiEndModelAccess()
function call:
sdaiEndModelAccess(model);
if (sdaiErrorQuery() != sdaiNO_ERR)
return;
sdaiCloseRepository()
and sdaiCloseSession()
functions respectively:
sdaiCloseRepository(repoCreate);
if (sdaiErrorQuery() != sdaiNO_ERR)
return;
sdaiCloseSession(session);
if (sdaiErrorQuery() != sdaiNO_ERR)
return;
Copyright © 2002 – 2020. Open Design Alliance. All rights reserved.
|